Customization: | Available |
---|---|
Theory: | Pressure Steam |
Type: | Pressure Steam Sterilization Equipments |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Essential Details
Name | Herbal Medicine Steam Sterilizer |
Brand | AIKSMED |
Model | MZY Series |
Application | Sterilization and drying of Spices,Herbal Medicine Powder,Healhy food,Cereals,Fish Meal,Dried Vegetables,Tea,Ect |
Door type
|
Hinger Door |
Chamber Volume | 360L,600L,800L,1000L,1200L, 1500L...4000L |
Design Pressure
|
-0.1/0.3 MPa |
Design Temperature | 144ºC |
Working Pressure | 0.25 MPa |
Sterilization Temperature | 105-136ºC |
Warranty
|
1 year
|
Origin
|
China |
Quantity(sets) | 1 - 1 | 2 - 5 | 6 - 10 | >10 |
Lead time (days) | 60 | 65 | 75 | To be negotiated |
Traditional disinfection treatment on herbal medicines are cobalt 60, ethylene oxide, alcohol, microwave, ozone and etc. However, it is difficult to ensure drug properties due to chemical residues, or the cost is expensive.
After repeated process verification, AIKSMED found that steam sterilization is the most suitable method for the herbal medicines, and hereby launches MZY series Herbal Medicine Steam Sterilizer. The structure is horizontal rectangular, internal and external steam heating. It is designed with a unique moisture-proof device, powder agglomeration in traditional steam sterilization can be avoided.
MZY Series Herbal Medicine Steam Sterilizer employs intense heat of saturated steam to build up pressure within the chamber and so kill bacterial spores by denaturing and coagulate their cell proteins through hydrolysis, then dry the loading with heat from jacket, while vacuuming out the humidity inside chamber.
Features:
1.Chamber designed and manufactured in accordance with China standard GB150 pressure Vessels .
2.Control system composed of PLC+ HMI, with data recording, printing and saving functions.
3. Equipped with a standard GMP temperature and pressure validation port.
4. Unique moisture-proof device.
Acceptance after sterilization:
*Mold and miscellaneous bacteria <10cfu/p.
*Powder is loose, not easy to agglomerate (different varieties, different situations).
*Powder no change color.
*Water content of powder < 5%.
Model | Volume | Chamber | Overall | Steam | Water | CA | Power | N/W | |
(M3) | (W*H*Dmm) | (W*H*Dmm) | (KG) | (KG) | (L) | (KW) | (KG) | ||
Hinged Door | MZY-0.36 | 0.36 | 600×600×1000 | 1280×1910×1540 | 20 | 350 | 40 | 1.5 | 800 |
MZY-0.6 | 0.6 | 610×910×1200 | 1280×1910×1540 | 35 | 400 | 80 | 2.4 | 1200 | |
MZY-0.8 | 0.8 | 610×910×1500 | 1280×1910×1790 | 45 | 500 | 100 | 2.4 | 1400 | |
MZY-1.0 | 1 | 610×910×1800 | 1280×1910×2100 | 55 | 520 | 120 | 3 | 1600 | |
MZY-1.2 | 1.2 | 680×1180×1500 | 1460×2000×1800 | 80 | 650 | 180 | 3 | 1900 | |
750×1100×1500 | 1450×1980×1720 | 80 | 650 | 180 | 3 | 1900 | |||
MZY-1.5 | 1.5 | 680×1180×1500 | 1450×1980×2050 | 80 | 660 | 220 | 3.8 | 2000 | |
750×1100×1820 | 1460×2000×2100 | 80 | 660 | 220 | 3.8 | 2000 | |||
MZY-2.0 | 2.0 | 750×1100×2450 | 1450×1980×2700 | 150 | 680 | 320 | 4.5 | 2500 | |
1000×1200×1700 | 1780×2100×2020 | 150 | 680 | 320 | 4.5 | 2500 | |||
MZY-2.5 | 2.5 | 1000×1200×1700 | 3195×1370×1960 | 160 | 800 | 450 | 5.5 | 2800 | |
2000×1200×2100 | 1780×2100×2420 | 160 | 800 | 450 | 5.5 | 2800 | |||
MZY-3.0 | 3.0 | 1000×1200×2500 | 3700×2100×2800 | 170 | 900 | 550 | 5.5 | 3200 | |
1000×1500×2000 | 1750×2100×2300 | 170 | 900 | 550 | 5.5 | 3200 | |||
MZY-4.0 | 4.0 | 1000×1200×3340 | 3700×2100×3640 | 220 | 200 | 650 | 6.5 | 4000 | |
1000×1500×2700 | 2000×2100×3030 | 220 | 1200 | 650 | 6.5 | 4000 | |||
MZY-5.0 | 5.0 | 1000×1500×3400 | 3635×1800×2200 | 320 | 1500 | 800 | 7.5 | 4500 | |
MZY-6.0 | 6.0 | 1000×1500×4000 | 2100×2100×4320 | 380 | 1600 | 1000 | 7.5 | 5000 |
AIKSMED is a distinguished expert in the field of sterilizer and autoclave manufacturing, boasting a legacy of over 30 years of industry expertise. Our commitment to innovation, continuous research and development, and a customer-centric approach have positioned AIKSMED as a global leader in providing advanced sterilization solutions.
Core Product Lines:
Cassette Autoclaves:
Tailored for dental and ophthalmology clinics.
Compact design, efficient performance, and ease of use.
Ensures the highest standards of instrument sterilization for healthcare professionals.
Laboratory Steam Sterilizers:
Customized solutions for research organizations and laboratories.
Precision sterilization for laboratory equipment and tools.
Adaptable features to meet the unique requirements of scientific applications.
Saturated Steam Sterilizers:
Engineered for the sterilization of garments and tools.
Comprehensive sterilization for textiles and instruments.
Advanced features for optimal performance and user convenience.
Superheated Water Cascade Sterilizers:
Designed for the pharmaceutical industry, specifically for liquid injections.
Utilizes cutting-edge superheated water cascade technology.
Ensures compliance with pharmaceutical standards, guaranteeing product safety and quality.
Evolution and Expansion:
With a foundation built on decades of experience, AIKSMED has expanded its product range beyond sterilizers and autoclaves. Our offerings now encompass a comprehensive suite of solutions, including Washing Machines, Biological Indicator Evaluation Resistometers (BIER/CIER), Automatic Steam Quality Monitors, and Temperature and Pressure Validation Systems. This expansion allows us to provide integrated services for sterilizer machine upgrading and validation.
Research and Development: AIKSMED is at the forefront of technological innovation, leveraging continuous research and development efforts to enhance sterilization solutions. Our R&D initiatives also extend to developing washing and disinfection solutions, demonstrating our commitment to comprehensive infection control.
Services:
AIKSMED takes pride in offering sterilizer machine upgrading and validation services. We understand the importance of staying current with evolving standards, and our services ensure that our clients' sterilization equipment meets and exceeds industry requirements.
Passion for Sterilization Innovation: Our motivation is fueled by a deep-seated passion for sterilization innovation. AIKSMED is dedicated to pushing the boundaries of technology, setting new industry standards, and providing cutting-edge solutions that address the evolving needs of our diverse clientele.
Welcome to AIKSMED: At AIKSMED, we invite you to explore a world of advanced sterilization and infection control solutions. Our commitment to excellence, coupled with a customer-focused approach, makes AIKSMED your trusted partner for all sterilization needs. Discover more and find superior solutions at AIKSMED!
1.What is FAT and SAT?
FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.
2. Is it possible for our autoclave and sterilizers idle for years to restart?