Overview

Basic Info.

Model NO.
MST
Electric Tension
380V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilize Temperature, Sterilize Time
Material
AISI316L/304 for Option
Name
Pulse Vacuum Steam Sterilizer
Application
Garments, Surgical Instrument, Tools, Liquids
Steam Supply
Built-in Steam Generator or External Steam Source
Model
Mst-50,60,80,100,120,135,150,185,200,300,450
Loading Capacity
60L,80L,100L,120L,135L,150L, 185L,200L,300L,450L
Door
Single/Pass-Through Double Doors
Terms of Payment
T/T, L/C
Customized
Available
Transport Package
Wooden Case
Specification
250L, 360L, 600L, 800L, 1000L, 1200L...4000L
Trademark
AIKSMED
Origin
China
HS Code
841920
Production Capacity
500 Sets/Year

Product Description

Essential details

Name Horizontal pulse vacuum  steam sterilizer
Brand AIKSMED
Model MST Series
Application Pharmaceutical, Biological engineering, Laboratory and other fields to sterilize fabrics, instruments, Lumen instruments, Rubber, Liquid
Door type
Double Doors
Chamber Volume 50L,60L,80L,100L,120L, 135L,150L,185L,200L,300L,450L
Design Pressure
-0.1/0.3 MPa
Design Temperature   144ºC
Working Pressure 0.23 MPa
Sterilization Temperature 105-138ºC
Warranty
1 year 
Origin
China
 
 
 
Supply Ability
 
Supply Ability: 500 Sets per Year
Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer
Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer
Packaging & delivery
 
Lead time:
Quantity(sets) 1 - 1 2 - 5 6 - 10 >10
Lead time (days) 60 65 75 To be negotiated

Working Principle

MST series Horizontal pulse vacuum steam sterilizer uses saturated steam as sterilization medium, through pulsating vacuum way, the saturated steam completely penetrates to the surface of the article, uses high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method.
 

   
Application
Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer
 
 
Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer
 
 

Features:
 

  1. Adopts microcomputer control technology, touch screen operation, the whole process (pulsating vacuum, heating, sterilization, exhaust steam, vacuum drying) procedures automatically run.
  2. Touch screen automatically displays operating status, temperature, pressure, time and other parameters and fault alarm information.
  3. Has 4 sterilization procedures including instruments, dressings, cavity instruments, rubber, liquid and custom, BD test and vacuum test for users to choose.
  4. Built-in vacuum pump, three times (can be set) pulsating vacuum, vacuum degree up to -0.090mpa can be fully pumped out of dressings and class A cavity instruments.
  5. Built-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.
  6. Vacuum drying system, fabric dryness less than 1%, instrument dryness less than 0.1%
  7. 0.22μm bacterial air filter.Ensure that the air breaking the vacuum is sterile air to avoid re-contamination
  8. Optional configuration of micro printer, real-time sterilization process and fault alarm information.

 

Product Parameters

 
Model Volume
(L)
Chamber 
(Φ×L)
Overall
(W*H*Dmm)
 Weight
(Kg)
Gross Weight
(Kg)
Packed
(W*H*Dmm)
POWER
MST-50B 50 316×620 870×600×520  65 77 97900×620 220V 50Hz  3.6Kw
MST-60B 60 386×500 985×600×1450  105 125 1085×700×1700 380V 50Hz  5.7Kw
MST-80B 80 386×700 985×600×1450  120 152 1085×700×1700 380V 50Hz  6Kw
MST-100B 100 386×860 1150×600×1450  140 175 1250×700×1700 380V 50Hz  6.6Kw
MST-120B 120 500×620 920×770×1550  200 250 1100×870×1800 380V 50Hz  9 Kw
MST-135B 135 500×700 1000×770×1550  225 270 1100×870×1800 380V 50Hz  9 Kw
MST-150B 150 500×780 1080×770×1550  240 290 1280×870×1800 380V 50Hz  12Kw
MST-185B 185 500×950 1250×770×1550  255 310 1350×870×1800 380V 50Hz  12Kw
MST-200B 200 500×1000 132770×1550  265 325 142870×1800 380V 50Hz  12Kw
MST-300B 300 65950 1350×900×1750 350 430 1450×1000×1950 380V 50Hz  18Kw
MST-450B 450 651360 1750×900×1750 450 550 1850×1000×1950 380V 50Hz  24Kw

Packaging & Shipping

Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer

 

Company Profile

 

AIKSMED is an expert manufacturer of diversed sterilizers and autoclaves, ranging from Cassette Autoclaves for dental &

ophthalmology clinics, Laboratory Steam Sterilizers for research organizations, Saturated Steam Sterilizers for garments and

tools, and Superheated Water Cascade Sterilizers for liquid injections in pharmaceutical industries.


 

Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer

 

 

After Sales Service

Auto Microcomputer Controled Autoclave Horizontal Cylindrical Pressure Steam Sterilizer

 

 

FAQ

1.What is FAT and SAT?


FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.

2. Is it possible for our autoclave and sterilizers idle for years to restart?

We have abundant experience to upgrade the sterilizers manufactured by world famous brand, glad we can provide you advice and solutions.

3. Regarding ampoule injection, How to choose between steam sterilizer and superheat water autoclave

Firstly these two kinds of autoclave sterilization machines got their own advantages on heating-up speed and cooling, uniform thermal distribution, and etc. But It mainly depends on the loads packing material and size, if glass ampoule, and size is 1ml, 2ml, 5ml, 10ml, we recommend steam sterilization with advantage of fast heating-up and less cost on utility consumption. However, if the container size over 10ml, then superheated water cascade sterilizer is more appropriate to reduce the broken rate after sterilizing, with advantage of regular heating-up, but it costs more on utility consumption and budget. Customer needs to consider based on own situations and long term operation.