80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer

Product Details
Customization: Available
Theory: Pressure Steam
Type: Pressure Steam Sterilization Equipments
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
14
Year of Establishment
2021-06-21
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
  • 80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
Find Similar Products
  • Overview
  • Working Principle
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • After Sales Service
  • FAQ
Overview

Basic Info.

Model NO.
MDVC
Certification
CE, EEC, ISO13485
Electric Tension
380V
LCD Display
With LCD Display
Ultra High Temperature Alarm
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Sterilize Temperature, Sterilize Time
Material
AISI316L/304 for Option
Name
Pulse Vacuum Steam Sterilizer
Application
Garments, Surgical Instrument, Tools, Liquids
Steam Supply
Built-in Steam Generator or External Steam Source
Model
Mdvd-35,50,80,100
Loading Capacity
35L, 50L, 80L, 100L
Door
Single Door
Terms of Payment
T/T, L/C
Customized
Available
Transport Package
Wooden Case
Specification
35L, 50L, 80L, 100L
Trademark
AIKSMED
Origin
China
HS Code
841920
Production Capacity
500 Sets/Year

Product Description

Essential details

Name Automatic Vertical Autoclave Steam Sterilizer
Brand AIKSMED
Model MDVC Series
Application Pharmaceutical, Biological engineering, Laboratory and other fields to sterilize fabrics, instruments, Lumen instruments, Rubber, Liquid
Door type
Single Door
Chamber Volume 35L, 50L, 80L, 100L
Design Pressure
-0.1/0.3 MPa
Design Temperature   144ºC
Working Pressure 0.23 MPa
Sterilization Temperature 105-138ºC
Warranty
1 year 
Origin
China
 
 
 
Supply Ability
 
Supply Ability: 500 Sets per Year
80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
Packaging & delivery
 
Lead time:
Quantity(sets) 1 - 1 2 - 5 6 - 10 >10
Lead time (days) 60 65 75 To be negotiated

Working Principle

MDVC series Vertical Autoclave Steam Sterilizer a small automatic high temperature and high pressure sterilization equipment with pressure steam as the medium.It is suitable for sterilization of fabrics, tools, rubber, liquid, culture medium, waste and other items in biomedical research institutes of biological laboratory and other levels.
 

   
Application
80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
 
 
80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer
 
Safety Device:
  1. Overtemperature automatic protection device: when the temperature exceeds the set, the system will automatically cut off the heating power supply, and sound and light alarm.
  2. Antidry burning protection device: when the water level is low and the heating tube is dry burning, the system will cut off the heating power supply automatically and give an audible and visual alarm.
  3. Door safety interlocking device: only when the door is closed in place, the power supply can be switched on to produce steam. There's pressure in the chamber, door won't open.
  4. Overpressure relief valve: when the opening pressure of the relief valve exceeds, the relief valve opens and relieves pressure.
  5. Heat preservation and heat insulation cover: the door cover made of heat preservation and heat insulation material is isolated, which is beautiful and can prevent the operator from scalding.
     

Features:

  1. Microcomputer program automatic control technology, LED display, touch button.
  2. Automatic program control of the whole process of water injection, heating, sterilization, exhaust steam and drying.
  3. With high temperature apparatus, low temperature apparatus, medium sterilization insulation, medium dissolution insulation and other procedures for users to choose.
  4. Sterilization process dynamic digital display, failure digital code alarm.
  5. Has positive pressure pulse steam exhaust function, completely eliminate the cold air in the sterilization room, to ensure steam saturation.
  6. Has fast exhaust steam and slow exhaust steam automatic control function, avoid liquid overflow when liquid sterilization.
  7. Has the function of automatic hold when power is off. After power is switched on again, it automatically continues to run from the program breakpoint.
  8. Built-in water tank, soda water circulation, no exhaust steam, clean and dry environment.
  9. Horizontal sliding quick door structure, self-expanding seal, simple and safe operation.

 

Product Parameters

 
Model Volume
(L)
Chamber 
(Φ×L)
Overall
(W*H*Dmm)
 Weight
(Kg)
POWER
MDVC-35 35 Φ316×450 476×616×830 50Kg 220V, 50Hz, 2.5Kw
MDVC-50 50 Φ316×667 476×616×990 65Kg 220V, 50Hz, 3 Kw
MDVC-80 80 Φ386×695 546×688×1030 75Kg 380V, 50Hz, 4.5Kw
MDVC-100 100 Φ386×860 546×688×1295 85Kg 380V, 50Hz, 5.4Kw

Packaging & Shipping

80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer

 

Company Profile

 

AIKSMED is an expert manufacturer of diversed sterilizers and autoclaves, ranging from Cassette Autoclaves for dental &

ophthalmology clinics, Laboratory Steam Sterilizers for research organizations, Saturated Steam Sterilizers for garments and

tools, and Superheated Water Cascade Sterilizers for liquid injections in pharmaceutical industries.


 

80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer

 

 

After Sales Service

80L Autoclave Vertical Cylindrical Pressure Pulse Vacuum Steam Sterilizer

 

 

FAQ

1.What is FAT and SAT?


FAT means Factory Acceptance Test, before delivering autoclaves, customer can send his technician or 3rd party personel to test machines in AIKSMED facotry, it usually takes 2~3 days. SAT means Site Acceptance Test, AIKSMED will send 1~2 engineers to user's site for equipment commissioning and staff training, ensuring production able to be carried out successfully.

2. Is it possible for our autoclave and sterilizers idle for years to restart?

We have abundant experience to upgrade the sterilizers manufactured by world famous brand, glad we can provide you advice and solutions.

3. Regarding ampoule injection, How to choose between steam sterilizer and superheat water autoclave

Firstly these two kinds of autoclave sterilization machines got their own advantages on heating-up speed and cooling, uniform thermal distribution, and etc. But It mainly depends on the loads packing material and size, if glass ampoule, and size is 1ml, 2ml, 5ml, 10ml, we recommend steam sterilization with advantage of fast heating-up and less cost on utility consumption. However, if the container size over 10ml, then superheated water cascade sterilizer is more appropriate to reduce the broken rate after sterilizing, with advantage of regular heating-up, but it costs more on utility consumption and budget. Customer needs to consider based on own situations and long term operation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier